产品中心
产品展示

  您当前的位置:首页 » 产品展示 » 色谱柱 » 500ul,, 岛津GC2010硅烷化定量管

产品名称: 500ul,, 岛津GC2010硅烷化定量管
产品型号: 500ul,,
品牌: 1356
产品数量:
产品单价: 面议
日期: 2024-05-11

500ul,, 岛津GC2010硅烷化定量管的详细资料

岛津GC2010硅烷化定量管

岛津GC2010硅烷化定量管详细信息:


浩瀚色谱采用硅烷化材质生产的气体定量管,防腐,吸附低,峰型对称。提供10ul-5000ul,可根据客户的实际要求定制。


容积:100ul,200ul,300ul,400ul,0.5ml.1ml.2ml.3ml
规格:1/16,1/8,Φ1.6;  Φ2: Φ3

气相色谱取样用:

特点:取样准确

材质:硅烷化/钝化

应用:非甲烷总烃,室内空气TVOC,硫化物,氟氯类,氨等

适用于安捷伦6890,7890,7820,8860,8890

岛津GC2010,GC-2014,GC-2018,GC-2030
赛默飞,瓦里安,布鲁克,PE,磐诺,福立,科晓/捷岛,鲁南瑞虹,惠分,上分,北分瑞利,川仪,华爱,科创,天瑞,天美等







岛津GC2010硅烷化定量管测试谱图:






Determination of eucalyptol content in transplanted Artemisia argyi using SE54 packed columnShimadzu hard glass column 2m * 5mmHH-PLOT U divinylbenzene ethylene glycol dimethylacrylic acidDetermination of Purity of Industrial Methanol by HH-PLOT U Capillary ColumnAnalysis of Non Methane Total Hydrocarbons in Fixed Pollution Source Waste Gas by Methane Column with Water ResistanceACT-1 activator modification of Benfel decarbonization process for measuring packed columnsShimadzu 2010 Carbon Molecular Sieve Filling ColumnSpecial filling column for the determination of methylhydrazine contentDetermination of trace hydrocarbon impurities in high-purity 1-butene using alumina capillary columnShimadzu 15% triethanolamine/CWA filled columnPorapak QS chromatographic stationary phase 80-100 meshDetermination of vitamin D3 in feed using silica gel column
Detailed information on silica gel columns for the determination of vitamin D3 in feed:
During the detection of vitamin D3 in feed using high-performance liquid chromatography, BHT (2,6-di-tert-butyl-p-cresol) has an impact on the determination process. When the content of vitamin D3 is low, the detection peak is prone to misjudgment, resulting in deviation of the detection results. Starting from the structure and experiments of BHT, optimizing the detection process can eliminate the influence of BHT on the detection of vitamin D3 in feed, achieving accurate qualitative and quantitative analysis.
Name: Liquid phase silicone column
Specification: 250MMX4.6MMX5uM
Article number: 2024051003
Application:
GB/T 17818-1999 Determination of Vitamin D3 in Feed High Performance Liquid Chromatography Method
GB/T 17818-1999 Determination of Vitamin D3 in Feed by High Performance Liquid Chromatography
GB5009.296-2023 National Food Safety Standard - Determination of Vitamin D in Foods
Silica gel column test spectrum for the determination of vitamin D3 in feed:
Shimadzu 15% triethanolamine/CWA filled column test spectrum: