  您当前的位置:首页 » 产品展示 » 色谱柱 » Shimadzu2010 岛津QF-1玻璃柱

产品名称: Shimadzu2010 岛津QF-1玻璃柱
产品型号: Shimadzu2010
品牌: 1356
产品数量:
产品单价: 面议
日期: 2022-05-24

Shimadzu2010 岛津QF-1玻璃柱的详细资料

岛津QF-1玻璃柱
岛津QF-1玻璃柱 详细信息:

名称:玻璃柱

型号:6%QF-1/Chromosorb W AW DMCS 80-100目

规格:2m*3mm
应用:
甲苯磺酸异构体的气相色谱分析
农药残留,有机磷,有机氯,666,DDT

岛津QF-1玻璃柱  测试谱图:


high quality
 Every column is rigorously tested

  Full range of chromatographic columns

  Reliable technical support

  Years of accumulated rich experience in chromatographic analysis and technical team

quality assurance:

  Use high-quality stainless steel tubing, glass tubing and chromatography packing to make a variety of high-efficiency packed chromatography columns

  If you need to use stainless steel filter mesh as the plug at both ends of the column, please specify when ordering

  If on-column injection is used, there will be a 6CM space at the front of the column inlet.

  To prevent the outflow of chromatographic packing, both ends of the column are blocked with silanized glass wool

  If the column is filled with valve injection or non-on-column injection, the column inlet is filled

  Various glass column configurations for gas chromatographs are available

  The entrance of the 2mm inner diameter glass column tube is equipped with a slope to facilitate sample injection

  Each column is fully conditioned and tested for rigorous quality evaluation



Precautions

Thank you for purchasing a chromatographic column produced by Haohan.

Every chromatographic column provided by Haohan has been aged. To ensure you get the best analytical separation effect, please aged for 1-2 hours before use. When aging, the carrier gas should be passed through for about 10 minutes. After the air in the column is completely replaced, the temperature is programmed to increase to the maximum operating temperature for aging.

To avoid contamination of the detector, do not connect the column to the detector during conditioning.

When the oven temperature is higher than room temperature, a small amount of oxygen in the carrier gas will damage the stationary phase in the chromatographic column, and the carrier gas must be further deoxygenated by a deoxygenation tube (it is recommended that the oxygen content of the carrier gas used should not exceed 1PPm)

When installing a chromatographic column, the product number should face the operator, and the left side is the injection port of the chromatographic column (or see the logo).

When disassembling the column, bring the column temperature down to room temperature before turning off the carrier gas.