产品名称: HH-CTY-II 10ppb除烃仪
产品型号: HH-CTY-II
品牌: 1356
产品数量:
产品单价: 面议
日期: 2021-10-06

HH-CTY-II 10ppb除烃仪的详细资料

10ppb除烃仪
10ppb除烃仪 详细信息:

内置微米过滤器
出口气体中总烷烃含量小于ppb
带数字PID控温的加热器
自动故障检测 抗干扰性强

     化工企业在生产过程中会产生含有大量烃类物质的废气,排放废气过程会对环境造成污染,在进行空气质量监测过程中,烃类物质不仅会影响在线空气质量监测设备监测结果的准确性,而且可能对设备的仪器管路造成污损。因此,对进入监测设备的空气进行预处理,尽可能除去烃类物质,得到纯净的空气源,对于提高监测的精度及保护监测设备关重要。

      当前除烃装置普遍需采用通过高温罐进行高温催化裂解,再依次通过硅胶、活性炭等过滤吸附,后得到洁净的空气。当前此类装置普遍面临高温催化部分难实现的问题,因市面上的高温催化剂普遍需加热到450°c工作,因此如何在有限的空间里达到一个好的加热控温效果,成为设计人员需解决的问题;冷空气直接进入高温罐,会大大降低催化剂的催化性能,故如何在入口前段解决气体预热的问题,也成为一个难点。



滕州市浩瀚色谱仪器技术服务有限公司,,研发专用除烃装置《10ppb除烃仪》,除烃后空气中碳氢化合物含量≤10ppb,此款仪器为浩瀚色谱,研制,目前正申请保护。




10ppb efficient hydrocarbon removal instrument
10ppb high-efficiency hydrocarbon removal instrument Details:

Built-in micron filter
The total alkane content in the outlet gas is less than ppb
Heater with digital PID temperature control
Automatic fault detection, strong anti-interference

In the production process of chemical companies, waste gas containing a large amount of hydrocarbons will be produced, and the process of discharging waste gas will pollute the environment. In the process of air quality monitoring, hydrocarbons will not only affect the accuracy of the monitoring results of online air quality monitoring equipment, Moreover, it may cause damage to the instrument pipeline of the equipment. Therefore, pre-treating the air entering the monitoring equipment to remove hydrocarbons as much as possible to obtain a pure air source is essential to improve the monitoring accuracy and protect the monitoring equipment.

Current hydrocarbon removal devices generally require high-temperature catalytic cracking through a high-temperature tank, followed by filtration and adsorption through silica gel, activated carbon, etc., and finally get clean air. At present, such devices are generally faced with the problem that the high-temperature catalytic part is difficult to achieve. Because the high-temperature catalysts on the market generally need to be heated to 450 °C, how to achieve a good heating and temperature control effect in a limited space has become a need for designers to solve The problem of cold air entering the high-temperature tank directly will greatly reduce the catalytic performance of the catalyst, so how to solve the problem of gas preheating in the front section of the inlet has also become a difficulty.



Tengzhou Haohan Chromatography Instrument Technology Service Co., Ltd. keeps pace with the times and develops a special high-efficiency hydrocarbon removal device "10ppb high-efficiency hydrocarbon removal instrument". After the hydrocarbon removal, the content of hydrocarbons in the air is ≤10ppb. , Currently applying for patent protection.