产品中心
产品展示

  您当前的位置:首页 » 产品展示 » 色谱柱 » HH-TEG 三甘醇分析专用填充柱

产品名称: HH-TEG 三甘醇分析专用填充柱
产品型号: HH-TEG
品牌: 1356
产品数量:
产品单价: 面议
日期: 2022-09-08

HH-TEG 三甘醇分析专用填充柱的详细资料

三甘醇分析专用填充柱
三甘醇分析专用填充柱详细信息:

规格:1m*3mm
型号:HH-TEG

二缩三乙二醇俗名三甘醇是有机的重要原料。容量分析采用吡啶催化的乙酰化,该法分析一个样品所需时间较长,且分析结果很不理想。而采用气相色谱分析的方法能克服这些缺点。

滕州市浩瀚色谱仪器技术服务有限公司,,,研发出专用填充柱,成功测定了三甘醇中二甘醇,乙二醇的含量,结果满意。

三甘醇分析专用填充柱测定谱图:




Quality assurance:

Use high-quality stainless steel tubes, glass tubes and chromatographic packing to make various packed chromatographic columns

If you need to use stainless steel filter screen as the plug at both ends of the column, please specify when ordering

If on-column injection is used, there will be a space of 6CM in front of the column inlet,

To prevent the chromatographic packing from flowing out, both ends of the column are blocked with silanized glass wool

If a chromatographic column with valve injection or non-on-column injection is used, the column inlet is filled

Available in various types of glass column configurations for gas chromatographs

The entrance of the 2mm inner diameter glass column tube is equipped with a slope to facilitate sample injection

Each chromatographic column has been fully aging and strict quality evaluation test

Precautions

Thank you for purchasing the column produced by Haohan.

Each chromatographic column provided by Haohan has been aged. To ensure the analytical separation effect you obtain, please aged for 1-2 hours before use. When aging, the carrier gas should be ventilated for about 10 minutes, and after the air in the column is cleaned up, use the program to increase the temperature to the highest use temperature for aging.

To avoid contamination of the detector, please do not connect the column to the detector during aging.

When the temperature of the column oven is higher than room temperature, a small amount of oxygen in the carrier gas will damage the stationary phase in the chromatographic column. The carrier gas must be further deoxidized by a deoxidizing tube (it is recommended that the oxygen content in the carrier gas used should not exceed 1PPm)

When installing the chromatographic column, the product brand should face the operator, and the injection port of the chromatographic column (or see label) on the left.

When disassembling the column, first lower the column temperature to room temperature, and then turn off the carrier gas.



Precautions

Thank you for purchasing the column produced by Haohan.

Each chromatographic column provided by Haohan has been aged. To ensure the analytical separation effect you obtain, please aged for 1-2 hours before use. When aging, the carrier gas should be ventilated for about 10 minutes, and after the air in the column is cleaned up, use the program to increase the temperature to the highest use temperature for aging.

To avoid contamination of the detector, please do not connect the column to the detector during aging.

When the temperature of the column oven is higher than room temperature, a small amount of oxygen in the carrier gas will damage the stationary phase in the chromatographic column. The carrier gas must be further deoxidized by a deoxidizing tube (it is recommended that the oxygen content in the carrier gas used should not exceed 1PPm)

When installing the chromatographic column, the product brand should face the operator, and the injection port of the chromatographic column (or see label) on the left.

When disassembling the column, first lower the column temperature to room temperature, and then turn off the carrier gas.